Circuit Breaker & Automatic Transfer Switch
Moulded Case Circuit Breaker
Air Circuit Breaker
Miniature Circuit Breaker
Residual Current Circuit Breaker
Dual Power Automatic Transfer Switch
Motor Protection Circuit Breaker
Surge Protective Device
Relay , Contactor , Starter & Frequency Inverter
Thermal Relay
General Relay
Timer Relay
Relay Socket
Solid State Relay
Contactor
Starter
Frequency Inverter
Power Equipment and Transformer and Solar
Voltage Stabilizer
Switching Power Supply
Control Transformer
Voltage Regulator
Ups & Eps
Inverter
Power Transformer
Solar Products
Instruments
KWH Meter
Panel Meter
Shunt
Current Transformer
Multimeter
Temperature Controller
Thermocouple & Thermal Resistance
Small Ptc Heater & Small Thermostat
Compass
Indicator & Switch & Warning Products
Indicator
Pushbutton Switch
Motive Switch
Limit Switch
Micro Switch
Toggle Switch
Foot Switch
Universal Changeover Switch
Float Switch
Warning Light
Siren
Warning Bell
Fuse & Disconnector
Low Voltage Fuse
Fuse Disconnector
High Voltage Fuse
Welder & Rectifier
Welder
Rectifier
Plug & Socket & Isolating Switch & Distribution Box
Industrial Plug & Socket
Weather Protected Isolating Switch
Distribution Board
Elctrical Accessories
Terminal
Cable Tie
Clips
Cable Gland
Cabinet Lock
Others
Axial Fan
Ex Products

● Address: NO.208, Weiqi Road, Yueqing Economic Development Zone, YueQing, Zhejiang, China.

● Worktime : 24 hours online   service

● Fax:0086 577 5293 1777

● Tel:0086 577 6273 1666

PTC Heater 15-150W HG140

Submit Comments
*Name
Phone
*Email
Address
*Message

1.Application
lectrical & Electronic enclosures
Telecommunications systems
Display panels
Automatic teller machines(ATM'S)
Access & Parking control systems
Ticket dispensers
2.Determining the required heater size
PH=(A x ΔT x K)-PV
PH=Required heating power for your application in Watts(W)
PV=Heating power generated by existing components(e.g.a
transformer)in Watts(W)
A=Exposed enclosure surface area in square meters(m2)
ΔT=Temperature differential between the desired minimum interior temperature and the Lowest possible external temperature of the enclosure in Kelvin(K), 1.8˚F=1˚C=1K K= Heat transmission coefficient of the enclosure material.
used:
Painted steel:5.5W/m2K
Stainless steel:3.7W/m2K
Aluminum:1.2W/m2K
Polyester/Plastc:3.5W/m2K
For outdoor appllcations it is recommended to double the heating power.

Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end custome/buyer in its final application.

Compact heater in PTC technology
Maintains minimum operating temperatures in enclosures
Helps to prevent failure of electronic components caused by condensation and corrosion
Heating power adjusts to ambient temperature
Push connectors for quick and easy wiring
DIN rail mountable
CE

2.Technical Data HG140

Operating voltageAC/DC 110-250V(also available in 12-48VDC)
Heating elementPTC resistor,self-regulating
Heating bodyAnodized extruded aluminum
Protection classI,test voltage 1600V
Protection typeIP20
ConnectionPush-type terminals for stranded and solid wire 3×AWG 20-16(0.5-1.5mm2)
MountinaClio for 35mm DIN rail(EN 50022)


Part.No.Power1)Max.Current2)LWeight
14000.0-0015W1.5A2.6”/65mm0.56 lbs(0.3kg)
14001.0-0030W3.0A2.6”/65mm0.66 lbs(0.3kg)
14003.0-0045W3.5A2.6”/65mm0.66 lbs(0.3kg)
14005.0-0060W2.5A5.5”/140mm1.10 lbs(0.5kg)
14006.0-0075W4.0A5.5”/140mm1.10 lbs(0.5kg)
14007.0-00100W4.5A5.5”/140mm1.10 lbs(0.5kg)
14008.0-00150W9.0A8.7”/220mm1.76 lbs(0.8kg)


1)at 68˚F(20˚C) ambient temparature. 2)Inrush current

 


1.Application
lectrical & Electronic enclosures
Telecommunications systems
Display panels
Automatic teller machines(ATM'S)
Access & Parking control systems
Ticket dispensers
2.Determining the required heater size
PH=(A x ΔT x K)-PV
PH=Required heating power for your application in Watts(W)
PV=Heating power generated by existing components(e.g.a
transformer)in Watts(W)
A=Exposed enclosure surface area in square meters(m2)
ΔT=Temperature differential between the desired minimum interior temperature and the Lowest possible external temperature of the enclosure in Kelvin(K), 1.8˚F=1˚C=1K K= Heat transmission coefficient of the enclosure material.
used:
Painted steel:5.5W/m2K
Stainless steel:3.7W/m2K
Aluminum:1.2W/m2K
Polyester/Plastc:3.5W/m2K
For outdoor appllcations it is recommended to double the heating power.

Specifications are subject to change without notice. Suitability of this product for its intended use and any associated risks must be determined by the end custome/buyer in its final application.

Compact heater in PTC technology
Maintains minimum operating temperatures in enclosures
Helps to prevent failure of electronic components caused by condensation and corrosion
Heating power adjusts to ambient temperature
Push connectors for quick and easy wiring
DIN rail mountable
CE

2.Technical Data HG140

Operating voltageAC/DC 110-250V(also available in 12-48VDC)
Heating elementPTC resistor,self-regulating
Heating bodyAnodized extruded aluminum
Protection classI,test voltage 1600V
Protection typeIP20
ConnectionPush-type terminals for stranded and solid wire 3×AWG 20-16(0.5-1.5mm2)
MountinaClio for 35mm DIN rail(EN 50022)


Part.No.Power1)Max.Current2)LWeight
14000.0-0015W1.5A2.6”/65mm0.56 lbs(0.3kg)
14001.0-0030W3.0A2.6”/65mm0.66 lbs(0.3kg)
14003.0-0045W3.5A2.6”/65mm0.66 lbs(0.3kg)
14005.0-0060W2.5A5.5”/140mm1.10 lbs(0.5kg)
14006.0-0075W4.0A5.5”/140mm1.10 lbs(0.5kg)
14007.0-00100W4.5A5.5”/140mm1.10 lbs(0.5kg)
14008.0-00150W9.0A8.7”/220mm1.76 lbs(0.8kg)


1)at 68˚F(20˚C) ambient temparature. 2)Inrush current