Circuit Breaker & Automatic Transfer Switch
Moulded Case Circuit Breaker
Air Circuit Breaker
Miniature Circuit Breaker
Residual Current Circuit Breaker
Dual Power Automatic Transfer Switch
Motor Protection Circuit Breaker
Surge Protective Device
Relay , Contactor , Starter & Frequency Inverter
Thermal Relay
General Relay
Timer Relay
Relay Socket
Solid State Relay
Contactor
Starter
Frequency Inverter
Power Equipment and Transformer and Solar
Voltage Stabilizer
Switching Power Supply
Control Transformer
Voltage Regulator
Ups & Eps
Inverter
Power Transformer
Solar Products
Instruments
KWH Meter
Panel Meter
Shunt
Current Transformer
Multimeter
Temperature Controller
Thermocouple & Thermal Resistance
Small Ptc Heater & Small Thermostat
Compass
Indicator & Switch & Warning Products
Indicator
Pushbutton Switch
Motive Switch
Limit Switch
Micro Switch
Toggle Switch
Foot Switch
Universal Changeover Switch
Float Switch
Warning Light
Siren
Warning Bell
Fuse & Disconnector
Low Voltage Fuse
Fuse Disconnector
High Voltage Fuse
Welder & Rectifier
Welder
Rectifier
Plug & Socket & Isolating Switch & Distribution Box
Industrial Plug & Socket
Weather Protected Isolating Switch
Distribution Board
Elctrical Accessories
Terminal
Cable Tie
Clips
Cable Gland
Cabinet Lock
Others
Axial Fan
Ex Products

● Address: NO.208, Weiqi Road, Yueqing Economic Development Zone, YueQing, Zhejiang, China.

● Worktime : 24 hours online   service

● Fax:0086 577 5293 1777

● Tel:0086 577 6273 1666

DZ30LE-32 Residual Current Operated Circuit Breaker

Submit Comments
*Name
Phone
*Email
Address
*Message

1.Application

DZ30LE-32 is used in the single phase circuit of AC 50Hz/60Hz, rated voltage 230V, used as electron shock protection. It can protect circuit form overload and short circuit. This product has advantages of small volume, high breaking capacity, live and zero wire are cut off at the same time, also protecting person from electric shock when the live wire connected opposite. It conforms with the standards of IEC61009.

2. Main Technical Parameter

TypeDZ30LE-32
Pole1P+N
Rated current (A)6,10,16,20,25,32
Rated voltage(V)230
Rated residual action current I△n(A)0.03
Rated residual non-action current I△no(A)0.015
Rated residual making/breaking capacity I△m(A)500
Type of instantaneous releaseC
Rated making/breaking capacity Im(A)4500


3. Applicable conducting wire:

Rated current(A)Norminal cross section of wire mm2
In ≤ 61
6< In ≤ 131.5
13 < In ≤ 202.5
20 < In ≤ 254
25 < In ≤ 326


1.Application

DZ30LE-32 is used in the single phase circuit of AC 50Hz/60Hz, rated voltage 230V, used as electron shock protection. It can protect circuit form overload and short circuit. This product has advantages of small volume, high breaking capacity, live and zero wire are cut off at the same time, also protecting person from electric shock when the live wire connected opposite. It conforms with the standards of IEC61009.

2. Main Technical Parameter

TypeDZ30LE-32
Pole1P+N
Rated current (A)6,10,16,20,25,32
Rated voltage(V)230
Rated residual action current I△n(A)0.03
Rated residual non-action current I△no(A)0.015
Rated residual making/breaking capacity I△m(A)500
Type of instantaneous releaseC
Rated making/breaking capacity Im(A)4500


3. Applicable conducting wire:

Rated current(A)Norminal cross section of wire mm2
In ≤ 61
6< In ≤ 131.5
13 < In ≤ 202.5
20 < In ≤ 254
25 < In ≤ 326