Circuit Breaker & Automatic Transfer Switch
Moulded Case Circuit Breaker
Air Circuit Breaker
Miniature Circuit Breaker
Residual Current Circuit Breaker
Dual Power Automatic Transfer Switch
Motor Protection Circuit Breaker
Surge Protective Device
Relay , Contactor , Starter & Frequency Inverter
Thermal Relay
General Relay
Timer Relay
Relay Socket
Solid State Relay
Contactor
Starter
Frequency Inverter
Power Equipment and Transformer and Solar
Voltage Stabilizer
Switching Power Supply
Control Transformer
Voltage Regulator
Ups & Eps
Inverter
Power Transformer
Solar Products
Instruments
KWH Meter
Panel Meter
Shunt
Current Transformer
Multimeter
Temperature Controller
Thermocouple & Thermal Resistance
Small Ptc Heater & Small Thermostat
Compass
Indicator & Switch & Warning Products
Indicator
Pushbutton Switch
Motive Switch
Limit Switch
Micro Switch
Toggle Switch
Foot Switch
Universal Changeover Switch
Float Switch
Warning Light
Siren
Warning Bell
Fuse & Disconnector
Low Voltage Fuse
Fuse Disconnector
High Voltage Fuse
Welder & Rectifier
Welder
Rectifier
Plug & Socket & Isolating Switch & Distribution Box
Industrial Plug & Socket
Weather Protected Isolating Switch
Distribution Board
Elctrical Accessories
Terminal
Cable Tie
Clips
Cable Gland
Cabinet Lock
Others
Axial Fan
Ex Products

● Address: NO.208, Weiqi Road, Yueqing Economic Development Zone, YueQing, Zhejiang, China.

● Worktime : 24 hours online   service

● Fax:0086 577 5293 1777

● Tel:0086 577 6273 1666

CJX2-K AC Contactor

Submit Comments
*Name
Phone
*Email
Address
*Message

1.Application

CJX2-K series AC contactor is suitable for use in the circuit up to the rate and frequentstarting, controlling the AC motor. The addition of auxiliary contact group to the contactor, com-bined with the proper thermal relay, can act to protect the circuit bound to overload. It conformsto IEC60947-4-1.

2.Specification

TypeCJX2-K06CJX2-K09CJX2-K12
Rating working voltage(V)380VAC-36912
AC-42.63.55
Appointed heating current(A)162020
The max current when turn on(A)380V6090120
660V72108144
The max current for turn off(A)380V487296
660V6090120
Three phases cage motors power whichcan be pulled AC3(KW)220v1.52.23
380v2.245.5
660v344
Operation frequency(time/hour)Electricity life(x104)AC-31200
AC-4300
Electrical lfieAC-35x106
AC-41x105
Mechanical life3x106


3. Outline and Mounting Dimension


1.Application

CJX2-K series AC contactor is suitable for use in the circuit up to the rate and frequentstarting, controlling the AC motor. The addition of auxiliary contact group to the contactor, com-bined with the proper thermal relay, can act to protect the circuit bound to overload. It conformsto IEC60947-4-1.

2.Specification

TypeCJX2-K06CJX2-K09CJX2-K12
Rating working voltage(V)380VAC-36912
AC-42.63.55
Appointed heating current(A)162020
The max current when turn on(A)380V6090120
660V72108144
The max current for turn off(A)380V487296
660V6090120
Three phases cage motors power whichcan be pulled AC3(KW)220v1.52.23
380v2.245.5
660v344
Operation frequency(time/hour)Electricity life(x104)AC-31200
AC-4300
Electrical lfieAC-35x106
AC-41x105
Mechanical life3x106


3. Outline and Mounting Dimension